Carrier weathermaker 8000 code 31. Carrier Weathermaker 8000 furnace code 31.
Carrier weathermaker 8000 code 31 I have a Weathermaker 8000, Model 58WAV091 Jan 30, 2024 · James Clark is the Ecommerce Manager of TechnicalHotandColdParts. At the end of the winter last year, it quit igniting at all (or so I thought), and I simply let it go until the past couple weeks. These furnaces were manufactured between about Carrier Weathermaker 8000 furnace code 31. If the blower is running but the furnace is not producing heat, there may be a problem with the furnace itself. I did notice that when I open the main cabinet (above where the circuit board resides) that the white 3" diameter PVC tube was blown out of its connection. 31. Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. Also for: 58zav. Read also: Carrier furnace code 31 (Solved) Possible Causes for Carrier Furnace Code 32 Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. airheatman Furnace, A/C and heat pump specialist. That’s why we designed the WeatherMaker 8000TS gas furnace for quality-conscious homeowners like you. In this video, I was able to resolve my issue related to code 31 on a Carrier fur Carrier Furnace not heating. The blower will run for a short time and off. 2-M95 National Standard of Canada, Natural Gas and Propane Installation Codes Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. com/airfactor2010/?ref=set Jan 7, 2012 · I have a carrier weathermaker 8000 58wav. 40,556 Satisfied Customers. If I interrupt the switch circuit I can hear the relay clicking and the inducer motor tries to spool up. I get code 32 on my weathermake 8000. The unit will ignite just fine when you first turn the thermostat on. In Canada, refer to the CAN/CGA-B149. When the pressure switch detects an issue, it triggers the code 31 error, impacting heating efficiency. I've been reading a lot about how the pressure switch might be at fault considering the code. what can i do to resolve this Matthew 14 years experience in the HVAC field of service, installation, Manual J & D calculations Oct 31, 2019 · I too am in agreement with the others. Carrier Weathermaker 8000 Furnace starts Nov 23, 2008 · Carrier 8000 Weathermaker-Code 24 blinking First, this is one of the worst furnaces I have ever had in a house. Blinks 31. 14 and 34 are ignition proving lockouts. Carrier furnace code 31 indicates a problem with the pressure switch. 2021. No glow. Carrier Furnace Code 13 [Solved] 3. WeatherMaker 8000 furnace pdf manual download. Bypass the Pressure Switch and the system fired up first time. holder for Industrial Ventilation In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA 54-1999/ANSI Z223. 54-1992/ANSI Z223. The first time he made sure nothing was plugged, checked and cleaned the flame sensor. I read on DIY about the flashing code 24. Replaced the Pressure Switch and the system turns on and the fan sounds like its spinning … read more Jan 3, 2020 · So my local carrier dealer came 3 times. William D. The superior attention to cabinet detail is obvious. 40,572 Satisfied Customers. The 58TUA Upflow Furnace is a great asset to Carrier’s list of product leadership in the gas furnace industry. I checked for codes, and it was flashing 31. I took out the hot surface igniter and it was white so I got a brand new one, factory direct to replace it. Carrier Furnace Code 34 and 14 [Fixed] 3 Carrier Weathermaker 8000 furnace code 31. Wear safety glasses and work gloves. It will startup, induction fan on, flames on, blower on for about 80 seconds. Thi Customer: Carrier Weathermaker 8000. There are no spot welds Feb 19, 2013 · Hi. If it is under warranty I have a Carrier Weathermaker 8000 58WAV furnace that gives a code 13, then after a reset and restart gives a code 33. com This video covers common problems with the 31 fault code on this furnace. Get the latest updates on new products and upcoming sales Customer: Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. Aug 21, 2023 · Status code 31 on a carrier furnace indicates that the pressure switch failed to close or reopened after closing. Carrier Furnace Code 32 [Solved] 2. May 14, 2016 · Look at the bearing/bushing. Bypassed the Pressure Switch and the system fired up first time. Pressure switch was Ok, Flame sensor seems Ok. Blinking code 31. Gotoman. Troubleshooting the Carrier Weathermaker 8000 can help you identify and fix issues before they become more serious problems. 40,489 Satisfied Customers. It is a reliable and efficient heating system, but like any other appliance, it may experience problems from time to time. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE detail is obvious. PS: See link for the troubleshooting manual at the bottom of this guide. I changed the fuse (3v) and I have a code 33. codes including the National Fuel Gas Code (NFGC) NFPA No. Blocked Vent Pipe May 25, 2024 · The Carrier Weathermaker 8000 is a popular gas furnace used in many homes across the United States. 1 View and Download Carrier WEATHERMAKER 8000 58WAV instruction manual online. The Carrier WeatherMaker 8000 features 1-piece, seamless, wrap-around construction. I loosened the rubber clasp, reinserted the tube and turned power on and off to restart the I have a weathermaker 8000, i keep getting #34 then #14 led code. The tech did not solve the problem, he masked it, potentially creating a dangerous situation. Jan 30, 2024 · Subscribe to our newsletter. I was getting the error code 34 and 14 on the Weathermaker which has many causes. I have a Carrier Weathermaker 8000 furnace -- periodically I get ignition lock out with code 1-4-- I've had service Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. I checked the chimney vent I have a Carrier Weathermaker 8000 58WAV furnace that gives a code 13, then after a reset and restart gives a code 33. Common Issues with Carrier Weathermaker 8000. Oct 24, 2013 · The first place to start is with the hose that goes between your inducer fan and the pressure switch. After a large snow storm the gas furnace started to not run normal causing it to lock out randomly. airheatman. View and Download Carrier WEATHERMAKER 8000 58ZAV installation and operating instructions manual online. Customer: I have a Carrier Weathermaker 8000 gas furnance and the LED is flashing code 33(Limit or flame roll-out switch is open). 40,590 Satisfied Customers. I have a carrier weathermaker 8000 furnace Carrier Weathermaker 8000 furnace code 31. holder for HVAC & Gas, Contractor, Estimator, Designer, Air Balance Certified, LG Master Commissioner, UNC Cert. The Carrier WeatherMaker 8000 gas furnace with ComfortHeat™ Technology keeps the temperature inside the house stable and efficient. WeatherMaker 8000 Deluxe 4-Way Multipoise Induced-Combustion Input Capacities: 45,000 thru 155,000 Btuh. It's a Carrier Weathermaker 9200 - not sure the exact model number off hand. My furnace is blowing cold air continuously and the thermostat won't come on or display anything (honeywell 7day programmer, digital). Technical Hot and Cold has been in heating and cooling since 1991 and first released their parts website, technicalhotandcoldparts. I checked the indicator light and verified it was throwing code 31, which per the manual is as follows: Pressure, draft guard, or auxiliary-limit (when used) switch did not close or reopened. Infinity thermostats are smart thermostats certified by ENERGY STAR that can be used with the heating and cooling units manufactured by Carrier. 40,503 Satisfied Customers. Downflow/Horizontal Induced-Combustion Furnaces. Oct 30, 2007 · Carrier Weathermaker (58MXA) code 31; Carrier Weathermaker (58MXA) code 31. In Canada, refer to the current REGISTERED QUALITY SYSTEM C a r r i e r C o r p o r a t i o n R E G I S T E R D F I R M I S O 9 01 # A 2 8 8 3 ® EFFICIENCY RATING CERTIFIED CERTIFIED Fig. If you are 100% sure he put in a higher temp limit switch, I would call the owner of the company and state that you are not happy with this set up, and you would like the limit switch replaced with the switch that was originally spec’d for this furnace. Hose connected to Pressure Switch is clear of any Oct 21, 2014 · 58SXC100-JG It's a high efficiency furnace which is supposed to condense water, but the amount I'm finding in the exhaust pipe seems excessive. I check everything, My Carrier Weathermaker 8000 two speed furnace has be turning off and on more often Welcome to Technical Hot and Cold’s Carrier replacement parts website. Also for: Weathermaker 8000. Changed Igniter. sjr. I replaced the ignitor, thinking it was the issue, with the following results. This status code is associated with overheating within the furnace causing the limit switch to open. A Carrier Weathermaker 8000 blows, but no Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. 39,674 Satisfied Customers. Hope this helps and saves you some money. to/3kfch0RGoPro Hero 8 Carrier Weathermaker 8000 furnace code 31. The last two mornings the temp was 66 in the morning and the thermostat from 68 did not turn the furnace on. I have a Carrier Weathermaker 8000 model Carrier Weathermaker 8000 furnace code 31. The second visit, he jumped the thermostat directly and the furnace ran fine for a little and told me my thermostat was bad. The furnace has been set to 68 degrees. 40,448 Satisfied Customers. Replaced the Pressure Switch and the system turns on and the fan sounds like its spinning but the blinking code 31 still lights up and the system won't fire the burners. I then changed the filter, and blew dust out of the unit and tightened up the spinning wheel in the upper part of the unit. I get a, LED light code 31 reading. Nov 3, 2013 · My Carrier WeatherMaker 9200 stopped heating with a code 31. I have a Carrier Weathermaker 8000 furnace Carrier Weathermaker 8000 furnace code 31. It then shuts down the flame and the induction motor. View and Download Carrier 58DLA product data online. I have a 59sc2a carrier furnace. I have a Carrier Weathermaker 8000. 2-M95 Natural Gas and Propane Installation Codes (NSCNGPIC). I have run into this problem before on another Carrier where a big wind d Mar 2, 2020 · Carrier Furnace Error Code 31 - Pressure Switch Furnace Issues [RESOLVED]. Low pressure switch. AC stops blowing Oct 1, 2014 · Carrier weathermaker 8000 model 58tma-10016 Code 32. Carrier Furnace Code 31 [Solved] 2. Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! See what your unit says for code 31. When we turned on the furnace, it would not light. Carrier Weathermaker 8000. No Carrier Weathermaker 8000 furnace code 31. WEATHERMAKER 8000 58ZAV furnace pdf manual download. I see that the pressure switch has two ports, but only one tube running from it into the duct work that connects to our basement ceiling. This switch ensures the furnace has the correct airflow for safe operation. 54-1999/ANSI Z223. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Carrier Weathermaker 8000 furnace code 31. The Carrier WeatherMaker 8000 features 1-piece, WeatherMaker 8000TS gas furnace enhances your overall comfort. It pulls a vacuum on the pressure witch to close it and also takes the exhaust out from heat exchanger,The only reason burners came on is while working with thew wires,you got the pressure switch open allowing the ignitor to light Jan 31, 2014 · Carrier Weathermaker 8000 codes 14 & 34 Jump to Latest 7. Have Carrier Weathermaker 8000 2 stage Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. The Carrier WeatherMaker 8000 features 1-piece, Carrier Weathermaker 8000 furnace code 31. Carrier Weathermaker 8000 Furnace starts Summary of Contents for Carrier WeatherMaker 8000 Page 1 Packed into the cabinet are the industry’s foremost dealer and homeowner features. Morning. At Carrier, we understand that indoor weather equipment is an investment in your family’s comfort. airheatman : The control board will not allow anything to happen before the inducer comes on. I have a weathermaker 8000 58wav. Carrier Weathermaker Oct 16, 2023 · How to Enter the Diagnostic Mode on a Carrier Infinity Thermostat?. 40,527 Satisfied Customers. Aug 21, 2023 · A carrier furnace code 32 indicates that the low-heat pressure switch is open. Move the "wheel" off to one "side", try it; move it to the other side, try it. https://www. The Carrier WeatherMaker 8000 Two-Speed features 1-piece, seamless, wrap-around construction. From time to time it will stop working, and then usually after several hours of reseting it, it will continue to work fine for several weeks at a time. My Carrier Weathermaker 8000 two speed Carrier Weathermaker 8000. nordyne g6cg 90+ The red light is on solid Aug 23, 2023 · Carrier furnace code 34 is an ignition proving fault that indicates that the flame was not sensed during the trial for the ignition period. I'm working on a carrier weathermaker 8000 VS unit blower motor quit working, the LED alarm is giving code 14 Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Jan 3, 2022 · Weatherman 8000 code 34. com in 2011. INDUCED-COMBUSTION GAS FURNACE. I have a weathermaker 8000, i keep getting #34 then #14 led code. We have 10 Carrier WeatherMaker 8000 manuals available for free PDF download: Installation And Operating Instructions Manual, Installation, Start-Up, And Operating Instructions Manual, Product Data, Installation, Start-Up And Operator's Manual, Manual, Repair Manual Carrier Weathermaker 8000 furnace code 31. Typically, the control will trigger the ignition process 3 more times before going to status code 14. Follow all safety codes. Here you can find Carrier parts for your heating and cooling needs. Also for: Weathermaker 8000, 58dla045-08, 58dla045-12, 58dla070-08, 58dla070-12, 58dla070-16, Carrier Weathermaker 8000 furnace code 31. 7 LINE VOLTAGE NEUTRAL HEAT SPARE 2 SPARE 1 BLOWER MOTOR COOL The superior attention to cabinet detail is obvious. Weathermaker 8000VS furnace pdf manual download. com and HVAC Controls Specialist (certified in Tridium and Carrier i-Vu controls) with a decade of experience at Technical Hot & Cold. Here is short video showing how to read the blinking e View and Download Carrier Weathermaker 8000VS manual online. It could be the silver pressure disc. S. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. Apr 3, 2011 · Carrier Weathermaker 8000. If there's slop or a noticeable difference in performance, inspect more closely and see if you can just replace the bearing/bushing. I have a Carrier Weathermaker 8000 furnace -- periodically I get ignition lock out with code 1-4-- I've had service Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE My Carrier Weathermaker 9200 isn't igniting to provide heat. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA No. What is the fix. 40,044 Satisfied Customers. We have 3 Carrier WEATHERMAKER 8000 58WAV Furnace manuals available for free PDF download: Installation, Start-Up And Operator's Manual, Installation, Start-Up, And Operating Instructions Manual, Installation And Operating Instructions Manual Product Data 58WAV WeatherMaker® 8000 Energy-Efficient Deluxe Upflow Furnace Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh Advanced Technology for Energy-Efficient Gas Furnaces Carrier leads the industry with its new WeatherMaker® 8000 InducedDraft Gas Furnace. 1-1999 and the Installation Standards, Warm Air Heating and Air Condition-ing Systems (NFPA 90B) ANSI/NFPA 90B. Topics manualzz, manuals, Carrier, Product data, WEATHERMAKER 8000 58WAV, Collection (last updated 12/31/2014) Feb 16, 2015 · Carrier Weathermaker 8000 mid-efficiency 58WAV upflow series 100 problem: flame cut-out in a continuing cycle, with duration of burner on time decreasing with each successive loss of flame: no lock-out, cycle continuous: code 31 after each burner out, LED returns to solid condition when ignition sequence restarts Dec 17, 2022 · The WeatherMaker 8000 furnace is made with the most advanced technology so that it is of the highest quality. Our neighbor came over to try and fix the problem, but, now we can't get the heater to come on at all, before while he was here he said that there were 2 codes, a Carrier Weathermaker 8000 blower was humming loudly yesterday Comfort Specialist Master Lic. There are no spot welds on the exterior surfaces of the WeatherMaker 8000 Two-Speed Furnace. edshvac. light gives me code 31. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Follow all safety codes. The furnace started to run fine for a little bit, then started short cycling with 31 code again. In the United States, follow all safety codes including the National Fuel Gas Code NFPA No. Hi, I am having a problem with my Carrier Weathermaker 8000, Last night when we went to bed, everything was fine, this morning when we woke up it was a chilly 61 degrees in our home. Contact options for registered users. Fan is The Carrier WeatherMaker 8000TS Gas Furnace will meet your home heating requirements. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Mar 7, 2011 · The furnace is 17 years old. Socode 43. 1-1992 (NFGC). Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Mar 7, 2011 · Gas and Oil Home Heating Furnaces - Carrier Weathermaker 9200 error code 31 - I just got home after being out of town for a week and found my house a chilly 53 degrees. 54- 1992/ANS1 Z223. The Carrier WeatherMaker 8000TS features 1-piece, seamless, wrap-around construction. The Carrier WeatherMaker 8000TS Gas Furnace will meet your home heating requirements. I need a pressure switch for a carrier Carrier Weathermaker 8000 furnace code 31. If the limit switch opens 5 times for at least 3 minutes each time during 1 thermostat cycle this will trigger the status code 13. 1-1992 and the Installation Standards, Warm Air Heating and Air Conditioning Systems (NFPA 90B) ANSI/NFPA 90B. I have a Carrier Weathermaker 8000, model # 58WAV111-16. Dec 1, 2024 · Overview of Carrier Furnace Troubleshooting Code 31. I had a second repair tech come take a look at it, and he was able to put in a temporary replacement for the inducer, which got it up and running for today, giving me time to decide whether I want to repair the furnace (replacing the inducer and the heat exchanger), or simply replace the Jan 23, 2023 · What is Carrier Furnace Code 12? Code 12 indicates that the thermostat is calling for heat, and the furnace is running the blower in response. I serves two purposes. First, a galvanized steel substrate provides resistance to rusting. 58DLA furnace pdf manual download. I have a Carrier Weathermaker 8000 with an Please see - https://www. The Carrier WeatherMaker 8000 Gas Furnace will meet your home heating requirements. Make sure the openings on both ends and the entire length of the hose is clear. Jump to Latest Code 31, 32 and 43 is a pressure switch lockout. My Carrier Weathermaker 8000 no longer has the Jan 18, 2021 · * Update: I replaced the filter and that fixed the problem. Inducer motor tries to start after 105 second run up cycle. replace flame sensor furnace shutting down after few seconds . Have Carrier Weathermaker 8000 2 stage The red light in the bottom cabinet is blinking four times slowly and then three times quickly. Second, it always blows out the inducer motor, which I found a way to buy wholesales and install myself 4 times in 10 years. 2-M91 Natural Gas and Propane Gas Installation Codes (NSCNGPIC). In Canada, refer to the current edition of the National Standard of Canada CAN/CGA-B149. In addition to providing precise, consistent indoor comfort, the WeatherMaker Jan 1, 2021 · Carrier WEATHERMAKER 8000 58WAV Product data. 40,615 Satisfied Customers. 1-1999. Non working furnace issue - Carrier View and Download Carrier WeatherMaker 8000 installation, start-up, and operating instructions manual online. Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE The Heat downstairs stopped working. There is also double protection for the cabinet. This furnace family provides the widest range of heating capacities available. what can i do to resolve this Matthew 14 years experience in the HVAC field of service, installation, Manual J & D calculations Follow all safety codes. Fan is Dec 27, 2015 · This video shows what I did to replace the igniter. Wear carrier error code 34 . Carrier weathermaker 8000 [ 1 Answers ] I have a carrier weathermaker 8000 furnace and it come on for about 20 seconds then the burners cut off, the fan keeps going and it just keeps repeating this cycle like it is short cycling Does anyone have any ideas because it is freezing in my house Carrier Weathermaker 8000 furnace code 31. Blocked drainageBlocked air ductPressure Switch FailureInducer MotorThe motor spins when the system attempts to fire up. Aug 27, 2012 · Carrier 8000TS, Weathermaker. By chatting and providing personal info, you understand and agree 12. Expert. I have a Carrier Model 58MXA08-12 with Serial number 3496A06075. facebook. Furnace, A/C and heat pump specialist. 1- and . Code 31 on weathermaker 8000 [ 3 Answers ] I have a weathermaker 8000 58wav. 40,113 Satisfied Customers. D. I know the problem was a dirty air filter (happened before) but the troubleshooting instructions don't say how to reset the switch. It can also mean that the low gas pressure switch is open. posted 15 years ago. Manufactured Aug 2020, installed Oct 2020, code 31 failure Manuals and User Guides for Carrier WEATHERMAKER 8000 58WAV Furnace. 5K views 3 replies 2 participants last post by yuri Jan 31, 2014 Posted by u/aekoops - 1 vote and 6 comments Jan 22, 2019 · Carrier Weathermaker 8000 - Flashing Codes Jump to Latest 13K views 7 replies 5 participants last post by user_12345a Jan 30, 2019 Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. Resoldered three (3) bad board connections, Cleaned Flame prover, so far. Oct 24, 2024 · Knowing these features and maintenance tips helps you keep your Carrier Weathermaker 8000 furnace running smoothly and efficiently, ensuring comfort during the harsh winter months. The ComfortHeat technology in the WeatherMaker 8000 gas furnace makes the airflow and comfort inside Code 31 on weathermaker 8000. I have a Weathermaker 8000. I- and . Our Weathermaker 8000 has been screeching intermittently over the last two months. Carrier Weathermaker 8000 furnaces encounter several common issues that can affect performance. I am trying to find out what size filter . Easy fix for a 31 Code. I reset the power on Customer: I have a Carrier Weather Maker 8000 furnace -- periodically I get ignition lock out with code 1-4-- I've had service technicians look at it several times and of course if runs perfect when they are here and for a while afterwards - sometimes it will go for a lengthy period with a lock out-- When it locks out and the lights are flashing I turn thermostat down and pull off the rear Jan 8, 2022 · Carrier furnace specs-model: Comfort 80% AFUE 110000 btuh 1-Stage Gas Furnace · 58SB0A110E21--20. Replaced. Aug 19, 2023 · A carrier furnace code 13 indicates that the limit switch is open. I have a Carrier Weathermaker 8000 Oct 29, 2012 · We have a Carrier Weathermaker 8000, model # cb5axa030000aaaa. PS: Check link to the troubleshooting manual at the bottom of this guide ( from page 19) Possible Causes For The Carrier Furnace Code 31 A few days ago we had a big windstorm and that caused the furnace to stop working. Carrier furnace model 58STA070 is flashing The Carrier WeatherMaker 8000 Gas Furnace will meet your home heating requirements. Or fastest delivery Tomorrow, Jan 27 . I have a Carrier Weathermaker 8000 with an Oct 27, 2015 · Carrier furnace 59SC5A120 pressure switch fault code #31Get It On AmazonMilwaukee 48-22-6330 Tongue and Groove Pliers Sethttps://amzn. Common Causes of Code 31. Jan 10, 2011 · A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Have Carrier Weathermaker 8000 2 stage I have a Carrier Weathermaker 8000 58WAV furnace that gives a code 13, then after a reset and restart gives a code 33. From reading the forum and manuals it looks like it could be one of several things. I have a weathermaker 8000ts and Manuals and User Guides for Carrier WeatherMaker 8000. 141 Series Sizes 050—135 Downflow/Horizontal Induced-Combustion. I have a Carrier Weathermaker 8000, model I have a Carrier Weathermaker 8000 furnace -- periodically I get ignition lock out with code 1-4-- I've had service Douglas Manufacture Rep for Major Brand, Technical Trainer, NATE Carrier Weathermaker 8000 furnace code 31. furnace soft lock out . Carrier Weathermaker 8000 furnace code 31. Tue, Oct 30, 2007 5:32 PM. Mar 12, 2012 · I have been dealing with an intermittently operating Carrier Weathermaker 8000 for the past several months. There are no spot welds on the Weathermaker 8000 deluxe 4-way multipoise induced-combustion input capacities: 45,000 thru 155,000 btuh (16 pages) Carrier Weathermaker 8000 furnace code 31. Yesterday we had a scare with no heat coming on after adjusting thermostat. I get a 31 It keep short cycling the E. Getting code 32 on my carrier weathermaker 8000. My Carrier Weathermaker 8000 two speed Carrier Weathermaker 8000 Runs intermitent - code 31 - tap control board - works again for a while, 1 -4 days. GrumpyGuy37 Posts: 6, Reputation Carrier Weathermaker 8000 Trouble Code [ 2 Answers ] 1-48 of 64 results for "carrier weathermaker 8000 parts" FREE delivery Fri, Jan 31 on $35 of items shipped by Amazon. 1 SEE SEPARATE LED STATUS CODE LABEL FOR INSTRUCTIONS ON CONDUCTING COMPONENT TEST AND READING STATUS CODES FROM LED. It is a Carrier 8000 weathermaker model 58WAV091-14 using natural gas heat and electric AC The error code is 3 (short) 1 (long). Also for: Weathermaker 8000ts, Weathermate 58sta, Weathermaker 8000, Weathermate 8000ts. hwao zcnul oubdq gjoozj qxc ltai zvugc afsv craetl kodoh